2P025A
Operation: This valve is a two-way, normally closed, direct-acting valve & does not require a minimum differential pressure to operate. As shown in the diagrams below, when the coil is de-energized (left diagram), the plunger rests on the main orifice & is held in place by the plunger spring force, sealing the valve. When the coil is energized (right diagram), the solenoid lifts the plunger & allows the working medium to flow through the orifice. The working medium & flow direction are indicated in purple in the diagrams.
Product Specifications
Valve Model 2P025-1/8A 2P025-1/4A Port Size 1/8” NPT 1/4” NPT Orifice 2.5mm 2.5mm Flow Coefficient (Cv) 0.23 0.23 Valve Type 2 Way, Normally Closed (NC) 2 Way, Normally Closed (NC) Action Direct Acting (Poppet) Fast Response Time: Direct Acting (Poppet)
Fast Response Time: <20msec
22SCFM at 100PSIDirect Acting (Poppet) Fast Response Time: Direct Acting (Poppet)
Fast Response Time: <20msec
22SCFM at 100PSIWetted Surfaces Valve Body: Engineered Acetal Plastic (Delrin POM) Seal: Viton (FKM) Armature Assembly: Stainless Steel Valve Body: Engineered Acetal Plastic (Delrin POM) Seal: Viton (FKM) Armature Assembly: Stainless Steel Seal Material Viton (FKM) Viton (FKM) Operating Temperature Media: 14°F to 176°F (-10°C to 80°C)
Ambient: 14°F to 122°F (-10°C to 50°C)
Media: 14°F to 176°F (-10°C to 80°C)
Ambient: 14°F to 122°F (-10°C to 50°C)
Operating Pressure 0 PSI to 150 PSI 0 PSI to 150 PSI Electrical Connections D: DIN
G: Grommet
E: Explosion Proof Coil (200C-E) 1/2” NPT Conduit Connection with 24in Three-Strand Wires
ATEX: Explosion Proof Coil (200C-ATEX)
DIN43650B Connection with 10ft Three-Wired Cable and Sleeve
D: DIN
G: Grommet
E: Explosion Proof Coil (200C-E) 1/2” NPT Conduit Connection with 24in Three-Strand Wires
ATEX: Explosion Proof Coil (200C-ATEX)
DIN43650B Connection with 10ft Three-Wired Cable and Sleeve
Coil Power 3-6.5W 3-6.5W Coil Duty 100% ED (Continuous Duty) 100% ED (Continuous Duty) Voltage Options 12VDC, 24VDC, 24VAC, 110/120VAC (50/60Hz), 220/240VAC (50/60Hz) 12VDC, 24VDC, 24VAC, 110/120VAC (50/60Hz), 220/240VAC (50/60Hz) Voltage Tolerance ±10% of Specified Voltage ±10% of Specified Voltage Ingress Protection IP65 IP65 Insulation Class H Class H Class Installation No Orientation Requirement Optimum Position: Flow Horizontal and Solenoid Vertical No Orientation Requirement Optimum Position: Flow Horizontal and Solenoid Vertical Service Liquid, Water, Air Liquid, Water, Air